“Data exchange” service offers individual users metadata transfer in several different formats. Citation formats are offered for transfers in texts as for the transfer into internet pages. Citation formats include permanent links that guarantee access to cited sources. For use are commonly structured metadata schemes : Dublin Core xml and ETUB-MS xml, local adaptation of international ETD-MS scheme intended for use in academic documents.
Export
Arapović - Savić, Marijana
Primjena fotogrametrije za analizu ortodontskih modela
Dozvoljavate samo preuzimanje i distribuciju dela, ako/dok se pravilno naznačava ime autora, bez ikakvih promena dela i bez prava komercijalnog korišćenja dela. Ova licenca je najstroža CC licenca. Osnovni opis Licence: http://creativecommons.org/licenses/by-nc-nd/3.0/rs/deed.sr_LATN. Sadržaj ugovora u celini: http://creativecommons.org/licenses/by-nc-nd/3.0/rs/legalcode.sr-Latn
Academic metadata
Doktorska disertacija
Medicinske nauke
Univerzitet u Banjoj Luci
Medicinski fakultet
Other Theses Metadata
Photogrammetry in the analysis of the orthodontic dental casts
Brzi razvoj informacionih tehnologija doveo je do široke upotrebe digitalnih studijskih modela u ortodonciji. Najpopularniji način digitalizacije modela je korišćenje 3D skenera, a zatim i mjerenja na 3D modelima, što zahtijeva dodatne i skupe hardverske i softverske resurse. U ovoj disertaciji je predstavljen alternativni pristup zasnovan na korišćenju fotogrametrije u novorazvijenom softveru OrthoPhoto4D koji izračunava i ispravlja greške nastale kao posljedice perspektivne distorzije. Na 50 studijskih modela mjerena je meziodistalna širina za 24 zuba, širina 12 segmenata od dva zuba, interkanina i intermolarna širina, te je izvršena Lundstromova i Boltonova analiza. Mjerenja su vršena u programu OrthoPhoto4D koji koristi četiri fotografije svakog mjerenog modela, koristi QR kodove za automatizaciju, računa udaljenost kamere i koriguje greške mjerenja izazvane perspektivom. Mjerenja su poređena sa rezultatima dobijenim na modelima generisanim 3D skenerom, te na gipsanim studijskim modelima. Analiza rezultata snažno ukazuje na to da ne postoji statistički značajna razlika između tri metoda. Zabilježene razlike takođe nemaju klinički značaj, jer su srednje vrijednosti do 0,2 mm za pojedinačne širine zuba, do približno 0,2 mm za segmente od dva zuba i ispod 0,3 mm za interkaninu i intermolarnu širinu. Poređenja rezultata Lundstromove i Boltonove analize takođe daje odstupanja koja nisu značajna u kliničkoj praksi. Sve zabilježene razlike su unutar očekivane greške mjerenja. Zaključak je da se opisani metod fotogrametrijskih mjerenja u programu OrthoPhoto4D može koristiti u dijagnozi i planiranju ortodontske terapije.
Rapid developments in information technologies lead to wider use of digital representations of dental study models in orthodontics. Most popular way of digitizing the models is to use a 3D scanner and then perform measurements on 3D models, which requires additional and expensive hardware and software resources. This dissertation presents an alternative approach based on the use of photogrammetry in newly developed OrthoPhoto4D software that calculates and corrects perspective distortion errors. 50 orthodontic dental casts were measured for the individual tooth widths for 24 teeth, 12 two-teeth segments, inter-molar and inter-canine distances, and Lundstrom and Bolton analysis were performed. Measurements were performed in OrthoPhoto4D software that uses four photographs of each model for measurements, uses QR codes for automation, calculates the camera position and corrects for perspective distortion caused errors in measurements. Obtained measurements are compared to the ones obtained on the models generated by structured light 3D scanner as well as the measurements performed on the plaster dental casts. Statistical analysis strongly indicates that there is no significant difference between the three methods. The recorded differences also have no clinical impact as they have mean values of 0.2 mm for individual tooth widths, approximately 0.2 mm for two teeth segments, and under 0.3 mm for both inter-canine and intermolar distances. Comparison of the results of the Lundstrom and Bolton analysis produces differences that are not significant in the clinical practice. All recorded differences fall within the expected measurement error. Conclusion is that the described photogrammetry measurements performed in OrthoPhoto4D can be used in diagnosis and therapy planning in orthodontic clinical practice.
ortopedija vilica, 3D skeniranje, fotogrametrija, studijski modeli, dijagnoza
orthodontic, 3D scanning, photogrammetry, dental casts, diagnosis
prema CERIF šifrarniku : B730
Serbian
Brzi razvoj informacionih tehnologija doveo je do široke upotrebe digitalnih studijskih modela u ortodonciji. Najpopularniji način digitalizacije modela je korišćenje 3D skenera, a zatim i mjerenja na 3D modelima, što zahtijeva dodatne i skupe hardverske i softverske resurse. U ovoj disertaciji je predstavljen alternativni pristup zasnovan na korišćenju fotogrametrije u novorazvijenom softveru OrthoPhoto4D koji izračunava i ispravlja greške nastale kao posljedice perspektivne distorzije. Na 50 studijskih modela mjerena je meziodistalna širina za 24 zuba, širina 12 segmenata od dva zuba, interkanina i intermolarna širina, te je izvršena Lundstromova i Boltonova analiza. Mjerenja su vršena u programu OrthoPhoto4D koji koristi četiri fotografije svakog mjerenog modela, koristi QR kodove za automatizaciju, računa udaljenost kamere i koriguje greške mjerenja izazvane perspektivom. Mjerenja su poređena sa rezultatima dobijenim na modelima generisanim 3D skenerom, te na gipsanim studijskim modelima. Analiza rezultata snažno ukazuje na to da ne postoji statistički značajna razlika između tri metoda. Zabilježene razlike takođe nemaju klinički značaj, jer su srednje vrijednosti do 0,2 mm za pojedinačne širine zuba, do približno 0,2 mm za segmente od dva zuba i ispod 0,3 mm za interkaninu i intermolarnu širinu. Poređenja rezultata Lundstromove i Boltonove analize takođe daje odstupanja koja nisu značajna u kliničkoj praksi. Sve zabilježene razlike su unutar očekivane greške mjerenja. Zaključak je da se opisani metod fotogrametrijskih mjerenja u programu OrthoPhoto4D može koristiti u dijagnozi i planiranju ortodontske terapije.