“Data exchange” service offers individual users metadata transfer in several different formats. Citation formats are offered for transfers in texts as for the transfer into internet pages. Citation formats include permanent links that guarantee access to cited sources. For use are commonly structured metadata schemes : Dublin Core xml and ETUB-MS xml, local adaptation of international ETD-MS scheme intended for use in academic documents.
Export
Đukić, Igor
Ispitivanje termičkog dejstva mašinskih rotirajućih instrumenata na kost
Dozvoljavate umnožavanje, distribuciju i javno saopštavanje dela, i prerade, ako se navede ime autora na način odredjen od strane autora ili davaoca licence. Ova licenca ne dozvoljava komercijalnu upotrebu dela. Osnovni opis Licence: http://creativecommons.org/licenses/by-nc/3.0/rs/deed.sr_LATN Sadržaj ugovora u celini: http://creativecommons.org/licenses/by-nc/3.0/rs/legalcode.sr-Latn
Academic metadata
Doktorska disertacija
Medicinske nauke
Univerzitet u Banjoj Luci
Medicinski fakultet
Other Theses Metadata
Examination of thermal effect of machine rotating instruments on the bone
177 listova
medicinske nauke - stomatologija - oralna hirurgija / medical science - dentistry - oral surgery
Selaković, Srećko (mentor)
Oralnohirurške intervencije, kao i implantološke, u današnjem savremenom dobu
podrazumijevaju preparaciju kosti uz pomoć mašinskih rotirajućih instrumenata ili svrdala. Rotacijom svrdala dolazi do frikcije i generacije toplote, koja se prenosi sa svrdla na koštano tkivo. Koštano tkivo dobro podnosi povećanje temperature do 47 stepeni Celzijusa (°C). Ako u toku preparacije kosti dođe do prekoračenja temperature kosti preko 47 °C, posljedično može da dođe do nekroze kosti, koja, u kombinaciji sa određenim stanjima pacijenta i bakterijama, može da dovede do osteomijelitisa. U implantologiji ovo prekoračenje temperature smatra se jednim od vodećih uzroka ranog odbacivanja implantata. Dosadašnja istraživanja o ovoj temi većinom su vršena u in vitro uslovima, sa arteficijelnim koštanim blokovima i uz pomoć kuplera kao mjernih uređaja. Rezultati svih istraživanja još nisu dali potpuni odgovor na pitanje koji je to bezbjedni način rada. Zajednički stav je da se smanjenjem broja obrtaja postiže manja temperatura. Cilj ovog
istraživanja bio je da ispita veličinu generisane toplote prilikom upotrebe najčešće korištenih oralnohirurških i implantoloških svrdala na koštano tkivo. Ispitivanje je sprovedeno na goveđim rebrima i ispitivano je ukupno sedam svrdala. Ispitivanja su podijeljena u dvije grupe. Prva grupa bila su ispitivanja bez hlađenja, a u drugoj grupi su vršena ispitivanja sa hlađenjem sterilnim 0,9% fiziološkim rastvorom, koji se koristi kao sredstvo hlađenja u toku oralnohirurških intervencija. Sva svrdla ispitivana su pri brzinama od 400, 600 i 1.000 obrtaja u minuti (Rpm), u vremenskom trajanju rada od 5, 10 i 20 sekundi (s) i pri obrtnom momentu od 25 i 50 Nm. Kao mjerni uređaj korištena je termovizijska kamera Guide infrared, a model MobIR M8. Svi dobijeni rezultati statističkisu obrađeni i međusobno upoređeni. Rezultati ovog istraživanja pokazali su da je moguća preparacija kosti i bez hlađenja ako se koriste izrazito mali broj obrtaja, povećanje obrtnog momenta i skraćeno vrijeme rada u kosti. U ovom istraživanju potvrđeno je da smanjenjem broja obrtaja dolazi do značajno manje generacije temperature, zatim da, ako se intervencija izvodi uz pomoć hlađenja, svi načini rada u ispitivanim brzinama, vremenskim i obrtnim momentima ne dovode do prekoračenja kritične temperature od 47 °C i predstavljaju apsolutno bezbjedan način rada.
Oral surgery as well as implant interventions in today's modern age include bone
preparation with the help of machine rotating instruments or drills. Rotation of the drill leads to friction and heat generation witch is transferred from the drill to the bone tissue. Bone tissue tolerates well the increase in temperature up to 47 degrees Celsius (°C). If the bone temperature exceeds 47 °C during bone preparation, bone necrosis occurs, which in combination with certain conditions of the patient as well as bacterial contamination can lead to osteomyelitis. In implantology, this excess temperature is considered one of the leading causes of early implant loss. Previous research on this topic has been mostly conducted in vitro, with artificial bone blocks and with the help of couplers as measuring
devices. The results of all research have not yet given a complete answer to a question, what is a safe way to work. The common position is that by reducing the number of revolutions, a lower temperature is achieved. The aim of this study was to examine the amount of heat generated when using the most commonly used oral surgical and implant drills on bone tissue. The test was performed on beef ribs, a total of seven drills were tested, the test was divided into two groups. The first group was studies without cooling, and the second group was performed with cooling, with sterile 0.9% saline, witch is used as a cooling agent during oral surgery. All drills were tested at speeds of 400, 600 and 1000 Rpm, the drilling time was 5, 10 and 20 seconds (s) and at a torque of 25 and 50 Nm. The guide MobIR M8 model infrared thermal imaging camera was used as a measuring device. All obtained results were statistically analysed and compared with each other. The
results of this study showed that bone preparation is possible without cooling if are used very low Rpms, increased torque and shortened bone drilling time. The results of this study confirmed that reduced speed leads to significantly lower temperature generation,then that if the intervention is performed with the help of cooling, all modes of operation at the tested speeds, times and torques do not exceed the critical temperature of 47 °C and they are absolutely safe manner of operation.
oralna hirurgija, implantologija, svrdla, termovizija, temperatura
oral surgery, implantology, drills, thermovision, temperature
prema CERIF šifrarniku : B730
Serbian
Oralnohirurške intervencije, kao i implantološke, u današnjem savremenom dobu
podrazumijevaju preparaciju kosti uz pomoć mašinskih rotirajućih instrumenata ili svrdala. Rotacijom svrdala dolazi do frikcije i generacije toplote, koja se prenosi sa svrdla na koštano tkivo. Koštano tkivo dobro podnosi povećanje temperature do 47 stepeni Celzijusa (°C). Ako u toku preparacije kosti dođe do prekoračenja temperature kosti preko 47 °C, posljedično može da dođe do nekroze kosti, koja, u kombinaciji sa određenim stanjima pacijenta i bakterijama, može da dovede do osteomijelitisa. U implantologiji ovo prekoračenje temperature smatra se jednim od vodećih uzroka ranog odbacivanja implantata. Dosadašnja istraživanja o ovoj temi većinom su vršena u in vitro uslovima, sa arteficijelnim koštanim blokovima i uz pomoć kuplera kao mjernih uređaja. Rezultati svih istraživanja još nisu dali potpuni odgovor na pitanje koji je to bezbjedni način rada. Zajednički stav je da se smanjenjem broja obrtaja postiže manja temperatura. Cilj ovog
istraživanja bio je da ispita veličinu generisane toplote prilikom upotrebe najčešće korištenih oralnohirurških i implantoloških svrdala na koštano tkivo. Ispitivanje je sprovedeno na goveđim rebrima i ispitivano je ukupno sedam svrdala. Ispitivanja su podijeljena u dvije grupe. Prva grupa bila su ispitivanja bez hlađenja, a u drugoj grupi su vršena ispitivanja sa hlađenjem sterilnim 0,9% fiziološkim rastvorom, koji se koristi kao sredstvo hlađenja u toku oralnohirurških intervencija. Sva svrdla ispitivana su pri brzinama od 400, 600 i 1.000 obrtaja u minuti (Rpm), u vremenskom trajanju rada od 5, 10 i 20 sekundi (s) i pri obrtnom momentu od 25 i 50 Nm. Kao mjerni uređaj korištena je termovizijska kamera Guide infrared, a model MobIR M8. Svi dobijeni rezultati statističkisu obrađeni i međusobno upoređeni. Rezultati ovog istraživanja pokazali su da je moguća preparacija kosti i bez hlađenja ako se koriste izrazito mali broj obrtaja, povećanje obrtnog momenta i skraćeno vrijeme rada u kosti. U ovom istraživanju potvrđeno je da smanjenjem broja obrtaja dolazi do značajno manje generacije temperature, zatim da, ako se intervencija izvodi uz pomoć hlađenja, svi načini rada u ispitivanim brzinama, vremenskim i obrtnim momentima ne dovode do prekoračenja kritične temperature od 47 °C i predstavljaju apsolutno bezbjedan način rada.